NCM B/E SERIES

NCM B Series Kit 20ft - AC Power.jpg
NCM Flow Meter Panel.jpg
NCM Serriies Ullttrrasoniic.png
Transducers for 0.5 to 2 inch pipes
dtt transdcuers for 2 inch pipe size and larger.jpg
NCM B Series Kit 20ft - AC Power.jpg
NCM Flow Meter Panel.jpg
NCM Serriies Ullttrrasoniic.png
Transducers for 0.5 to 2 inch pipes
dtt transdcuers for 2 inch pipe size and larger.jpg
sold out

NCM B/E SERIES

0.00

Non-Intrusive Clamp-On Ultrasonic, Transit Time Flow Meter

Features

  • Works on plastic and metal pipes 0.5" to 100"

  • Measures bi-directional flow 0.1 FPS to 40 FPS

  • A/C and D/C powered models

  • Large backlit LCD display with keypad shows flow rate and total

  • Rugged NEMA 4X enclosure

  • Standard outputs include 4-20 mA, Modbus RTU and pulse

  • Advanced communications options available (Ethernet, BACnet, TCP/IP, and more)

CALL/EMAIL US FOR PRICING

LEAD-TIME IS APPROXIMATELY 2 WEEKS

Add To Cart

The Non-contact Meters NCM Series Clamp-on Ultrasonic Transit Time Flow and Energy Meter installs in seconds on most pipe materials. Measures full pipe, clean to dirty liquid applications. Typical examples include water, well water, chilled water, hot water, city water, cooling tower water, glycol, deionized water, sea water, sewage, acids and more.

The NCM is available in two versions: NCMB, a stand-alone flow meter and NCME, an energy flow meter monitoring flow and dual clamp-on RTDs. The energy flow meter measures energy usage in BTU or Tons and is ideal for retrofit, chilled water and other HVAC applications.

Review our specification data sheet for additional details on the NCMB and NCME series or contact us if you still need help deciding which configuration will work best for your needs.


OPTIONS

Select a complete kit from the left or contact us for a customized sales quote, see configurable options on the right for more details

CONFIGURED KITS (AC POWER VERSION)

NCM B Series Kit (20 ft of Sensor Cable / AC Power)

Dedicated ultrasonic flow meter kit (AC Powered) for 2 to 36 inch pipes. Includes backlit rate/total display/transmitter, clamp-on transducer set (DTTN-020-N000-N) for pipes 2 to 36 inches with 20 ft of sensor cable, 95-264 VAC power, 4-20 mA, RS485 Modbus, and two alarm outputs, mounting kit, and manual.

NCM B Series Kit (50 ft of Sensor Cable / AC Power)

Dedicated ultrasonic flow meter kit (AC Powered) for 2 to 36 inch pipes. Includes backlit rate/total display/transmitter, clamp-on transducer set (DTTN-050-N000-N) for pipes 2 to 36 inches with 50 ft of sensor cable, 95-264 VAC power, 4-20 mA, RS485 Modbus, and two alarm outputs, mounting kit, and manual.

NCM B Series Kit (100 ft of Sensor Cable / AC Power)

Dedicated ultrasonic flow meter kit (AC Powered) for 2 to 36 inch pipes. Includes backlit rate/total display/transmitter, clamp-on transducer set (DTTN-100-N000-N) for pipes 2 to 36 inches with 100 ft of sensor cable, 95-264 VAC power, 4-20 mA, RS485 Modbus, and two alarm outputs, mounting kit, and manual.

Voltage Options

AC (Universal) 96-264 VAC

20 - 28 VAC

11 - 28 VDC

Communication Options

BACnet MS/TP

BACnet MS/TP 100/1000 Base-T (Ethernet/IP, BACnet/IP Modbus TCP/IP)

Modbus RTU and 10/100 Base-T (Ethernet/IP, BACnet/IP Modbus TCP/IP)

Transducers (one pair) 2 Inch Pipe and Larger

DTTN Standard 2 to 36 Inch, 1 MHz (Max Temp. 250°F)

DTTH High Temperature 2 to 36 inch (Max Temp. 350°F)

DTTL Large Pipe Size 28 to 100 inch, 0.5 MHz (Max Temp. 194°F)

DTTS Ultrasonic Transducers (0.5 to 2 Inch Pipes) CALL

Cable Length

20ft (Coaxial cable)

50ft (Coaxial cable)

100 (Coaxial cable)

Custom Cable Length Available