Keller Preciseline High Accuracy Pressure Transmitter

from $600.00
ITEM:

Brand: Keller Pressure - Precision Pressure Measurement for Demanding Industrial Applications

The Keller Preciseline pressure transmitter combines outstanding accuracy, dual analog and RS485 digital outputs, and rugged industrial reliability for demanding pressure monitoring applications. Designed for seamless integration with SCADA, PLC, telemetry, and process control systems, the Preciseline is ideal for water, wastewater, industrial automation, hydraulic, and environmental monitoring applications.

Key-Features

  • High accuracy pressure measurement with outstanding Total Error Band (TEB) performance

  • Dual analog and RS485 digital outputs for flexible system integration

  • Compatible with SCADA, PLC, telemetry, and industrial automation systems

  • Supports up to 128 transmitters on a single RS485 communication bus

  • Available in pressure ranges from 2 to 15,000 PSI

  • Custom pressure ranges and cable lengths available to meet application requirements

  • Rugged industrial design for demanding environmental and process applications

  • NSF/ANSI 61 and 372 certified for drinking water applications

  • Integrated lightning and surge protection on 4–20 mA models

  • Fast assembly to customer specifications with quick lead times

  • Ideal for industrial process monitoring, water systems, hydraulics, pumps, tanks, and OEM equipment

  • Reliable long-term performance in remote and harsh operating environments

Receive a quote in one hour or less. Contact AWM Instruments by phone or email for pricing, availability, and technical assistance.

Brand: Keller Pressure - Precision Pressure Measurement for Demanding Industrial Applications

The Keller Preciseline pressure transmitter combines outstanding accuracy, dual analog and RS485 digital outputs, and rugged industrial reliability for demanding pressure monitoring applications. Designed for seamless integration with SCADA, PLC, telemetry, and process control systems, the Preciseline is ideal for water, wastewater, industrial automation, hydraulic, and environmental monitoring applications.

Key-Features

  • High accuracy pressure measurement with outstanding Total Error Band (TEB) performance

  • Dual analog and RS485 digital outputs for flexible system integration

  • Compatible with SCADA, PLC, telemetry, and industrial automation systems

  • Supports up to 128 transmitters on a single RS485 communication bus

  • Available in pressure ranges from 2 to 15,000 PSI

  • Custom pressure ranges and cable lengths available to meet application requirements

  • Rugged industrial design for demanding environmental and process applications

  • NSF/ANSI 61 and 372 certified for drinking water applications

  • Integrated lightning and surge protection on 4–20 mA models

  • Fast assembly to customer specifications with quick lead times

  • Ideal for industrial process monitoring, water systems, hydraulics, pumps, tanks, and OEM equipment

  • Reliable long-term performance in remote and harsh operating environments

Receive a quote in one hour or less. Contact AWM Instruments by phone or email for pricing, availability, and technical assistance.

 

Product Description

The Keller Preciseline high accuracy dual output pressure transmitter with 1/4”-18 NPT Male process connection delivers reliable and precise performance for both new and existing pressure measurement applications. Available in pressure ranges from 2 to 15,000 PSI, the Preciseline provides outstanding Total Error Band (TEB) accuracy for demanding industrial, environmental, and process monitoring systems.

Designed for versatile system integration, the Preciseline features dual outputs including one analog signal (4–20 mA or voltage) and one RS485 digital output. This flexible configuration ensures seamless compatibility with SCADA systems, PLCs, telemetry platforms, and industrial automation networks. The RS485 communication capability also allows up to 128 Preciseline pressure transmitters to be connected on a single communication bus.

Each Preciseline pressure transmitter is assembled in the USA to customer specifications, including custom pressure ranges and cable lengths, with typical production times of three business days or less. The transmitter is certified to NSF/ANSI 61 and NSF/ANSI 372 standards for drinking water applications, making it ideal for municipal water systems, industrial process control, and environmental monitoring.

Models equipped with 4–20 mA analog output also include integrated lightning protection at no additional cost. This built-in surge protection safeguards the transmitter against fast-rising electrical transients and is backed by a lifetime guarantee against electrical surge damage.


Keller Preciseline Pressure Transmitter Specifications

The Keller Preciseline is a high accuracy industrial pressure transmitter designed for demanding pressure measurement applications where reliable analog and digital communication are required. With dual output capability and rugged construction, it is ideal for SCADA, PLC, data logger, telemetry, and process control systems.

Pressure Range

2 to 15,000 PSI

Output Signals

4–20 mA / Voltage + RS485 Digital Output

Accuracy

High accuracy performance with excellent Total Error Band (TEB)

Communication

Analog output for control systems and RS485 for digital monitoring

System Compatibility

SCADA, PLC, DCS, data loggers, telemetry systems, and industrial automation platforms

Typical Applications

Process pressure monitoring, pumps, compressors, hydraulics, water systems, and OEM equipment

Product Type High accuracy industrial pressure transmitter
Model Keller Preciseline
Pressure Range 2 to 15,000 PSI
Available Outputs 4–20 mA, voltage, and RS485 digital communication
Primary Use Industrial pressure measurement and process monitoring
Integration Compatible with SCADA, PLC, data logger, telemetry, and control systems
Common Industries Water, wastewater, industrial process, manufacturing, utilities, hydraulics, and OEM systems

Need Help Selecting the Right Pressure Range or Output?

Contact AWM Instruments for pricing, availability, configuration support, and help selecting the right Keller pressure transmitter for your application.

Request Pricing & Availability

Industries Using The Preciseline Pressure Transmitter

  • Water and wastewater

  • Industrial manufacturing

  • Process automation and control

  • Municipal utilities

  • Environmental monitoring

  • Energy and utilities

  • Food and beverage processing

  • Agriculture and irrigation

  • Oil and gas support systems

  • OEM machinery and equipment manufacturing

  • Research and laboratory facilities

  • Chemical and industrial processing

Typical Applications

  • Industrial process pressure monitoring

  • Water and wastewater treatment systems

  • SCADA and PLC monitoring systems

  • Pump and compressor monitoring

  • Hydraulic and pneumatic systems

  • Tank level and pressure monitoring

  • OEM equipment integration

  • Remote telemetry and data logging systems

  • Drinking water distribution systems

  • Environmental monitoring applications

  • Pressure test benches and laboratory systems

  • Utility and infrastructure monitoring