Product Overview
The Seametrics EX100/200 Series provides adjustable depth electromagnetic flow measurement for conductive liquids in full pipes. Brass and 316 stainless steel options support material selection for water, wastewater, irrigation, and industrial service. With no rotor or bearings, the sensor can measure clean or dirty liquids without moving components.
The EX110 covers 3–10-inch pipes, while the EX210 covers 10–48-inch pipes. A pulse output connects to compatible PLCs or monitoring equipment. Optional FT430 or FT440 indicators provide local flow rate and total displays; the FT440 also provides a 4–20 mA output.
Specifications at a Glance
| Technology | Adjustable depth electromagnetic insertion |
|---|---|
| EX110 pipe sizes | 3–10 inches |
| EX210 pipe sizes | 10–48 inches; up to 72 inches with optional extension |
| Sensor materials | Brass or 316 stainless steel |
| Power supply | 12–24 VDC; full-power and low-power versions |
| Minimum conductivity | 20 µS/cm |
| Flow velocity | 0.28–20 ft/s |
| Accuracy | ±1% of full scale |
| Maximum pressure | 200 psi |
| Fluid temperature | 32–200°F |
| Sensor output | Opto-isolated square-wave pulse; 500 Hz at 20 ft/s |
Select fittings and options for the specific installation. See the datasheet for configuration details and limits.
Typical Applications
- Municipal water supply and distribution
- Irrigation pipelines and water delivery
- Conductive industrial process liquids
- Clean and dirty water flow monitoring
Before You Select a Model
Confirm actual pipe dimensions, fitting configuration, liquid conductivity, flow range, pressure, temperature, and required output.
The pipe must remain full. Review straight-pipe requirements, sensor orientation, and insertion depth in the installation manual.
Need Hot-Tap Installation?
EX150/250 models provide the isolation-valve configuration for installation or servicing without shutting down the line. Specify these models when hot-tap capability is required.
Documents & Installation
Product Datasheet & Flow Ranges
Review specifications, pipe-size flow ranges, materials, and model options.
View EX100/200 Product Datasheet (PDF)Installation & Ordering Information
Review positioning, depth adjustment, electrical connections, and maintenance. Ordering tables are included in the product datasheet.
View Installation Manual (PDF) View EX11x/21x Quick Start Guide (PDF) View Model & Ordering Options (PDF)