Product Overview
The Seametrics EX150/250 Series measures conductive liquids in full pipes where interrupting service is difficult. Its hot-tap design uses an isolation valve to allow sensor installation and removal under pressure, following the manufacturer’s installation procedures.
The EX150 fits 3–10-inch pipes, while the EX250 fits 10–48-inch pipes. Adjustable insertion depth and brass or 316 stainless steel construction accommodate different installations. The sensor has no moving parts and provides a pulse output for compatible controllers or optional flow indicators.
Specifications at a Glance
| Technology | Adjustable depth electromagnetic insertion |
|---|---|
| EX150 pipe sizes | 3–10 inches |
| EX250 pipe sizes | 10–48 inches; up to 72 inches with optional extension |
| Installation fitting | 2-inch FNPT; full-port isolation valve assembly |
| Valve options | Bronze standard; 316 stainless steel optional for stainless steel models |
| Sensor materials | Brass or 316 stainless steel |
| Power supply | 12–24 VDC; full-power and low-power versions |
| Minimum conductivity | 20 µS/cm |
| Flow velocity range | 0.28–20 ft/s |
| Accuracy | ±1% of full scale |
| Maximum pressure | 200 psi |
| Fluid temperature | 32–200°F |
| Sensor output | Opto-isolated square-wave pulse; 500 Hz at 20 ft/s |
Select fittings and options for the specific installation. See the datasheet for configuration details and limits.
Typical Applications
- Municipal water supply and distribution
- Irrigation pipelines and water delivery
- Conductive industrial process liquids
- Clean and dirty water flow monitoring
Before You Select a Model
Confirm actual pipe dimensions, fitting configuration, liquid conductivity, flow range, pressure, temperature, and required output.
The pipe must remain full. Review straight-pipe requirements, sensor orientation, and insertion depth in the installation manual.
Displays & Output Options
Pair with an FT430 for local flow rate and total indication, or an FT440 when a 4–20 mA output is needed. The sensor requires its own external power supply; an FT440-equipped EX sensor cannot be powered solely by the 4–20 mA loop.
Documents & Installation
Product Datasheet & Flow Ranges
Review specifications, pipe-size flow ranges, materials, and model options.
View EX150/250 Specifications & Flow Ranges (PDF)Installation & Ordering Information
Review hot-tap installation requirements, depth adjustment, wiring, and maintenance. The shared EX100/200 Series documents include EX150/250 models and ordering tables.
View Installation Manual (PDF) View EX15x/25x Quick Start Guide (PDF) View Model & Ordering Options (PDF)