Dissolved Oxygen Controller/Transmitter

from $258.00

Brand: Jenco

2 models two choose from

3931 Features 4 - 20 mA Output

3951 Features Modbus RS-485 output

Model:
Quantity:
Add To Cart
3931 Dissolved Oxygen Transmitter 4-20 mA.png

Specifications

  • DO Range0.00 to 40.00 mg/L
  • DO Resolution0.01 mg/L
  • DO Accuracy±0.2 % F.S.
  • DO% saturation Range0.0 to 400.0 %
  • DO% saturation Resolution0.1 %
  • DO% saturation Accuracy±0.2 % F.S.
  • Temperature Range-10.0 to 80.0 °C automatic or manual
  • Temperature Resolution0.1 °C
  • Temperature Accuracy±0.3 °C
  • Barometric Pressure Compensation Range600 to 4000 mbar manual
  • Salinity Compensation Range0.0 to 49.9 ppt manual
  • DO Calibration1 or 2 point
  • Product Calibrationhave
  • Type of ElectrodePolarographic
  • Temperature SensorThermistor, 22 Kohm at 25 °C
  • Current Output4 to 20 mA isolated and programmable
  • Maximum Load500 ohm
  • Isolation Voltage500 V DC
  • Power100 to 240 V AC , 50/60 Hz
  • CaseIP65, 1/8DIN case, depth 90 mm
  • Weigh290 g

Model 3931 ( with 4-20 mA Output)

BRAND: JENCO

Description

DO & temperature transmitter with an isolated & reversible 4 to 20 mA current output, stored calibration data, backlit LCD for DO and temperature, universal power supply 110 to 240 VAC and packaged in an easy to install plastic panel mount water resistant 1/8 DIN IP-65 case. Uses Hamilton Company Oxysens and Easyferm DO electrodes.

  • Easy to install 1/8 DIN plastic casing

  • Clear LCD dissolved oxygen or temperature with backlight

  • Calibration data is stored in memory and is ready for use on power-up

  • Universal power supply input from 100-240 VAC

  • Automatic or manual temperature compensation

  • Isolated and reversible 4 ~ 20 mA current output for DO allows it to be used as a proportional output

  • CE and RoHS complain


 
3951 Dissolved Oxygen Transmitter Modbus.png

Specifications

  • DO Range 0.00 to 40.00 mg/L
  • DO Resolution 0.01 mg/L
  • DO Accuracy ±0.2% F.S.
  • DO% saturation Range 0.0 to 400.0 %
  • DO% saturation Resolution 0.1 %
  • DO% saturation Accuracy ±0.2% F.S.
  • Temperature Range -10.0 to 80.0 °C automatic or manual
  • Temperature Resolution 0.1 °C
  • Temperature Accuracy ±0.3 °C
  • Barometric Pressure Compensation Range 600 to 4000 mbar manual
  • Salinity Compensation Range 0.0 to 49.9 ppt manual
  • DO Calibration 1 or 2 point
  • Type of Electrode Polarographic
  • Temperature Sensor Thermistor, 22k ohm at 25 °C,
  • Communication Output RS-485 Modbus standard protocol
  • Power 100 to 240 V AC , 50/60 Hz
  • Case IP65, 1/8DIN case, depth 90 mm
  • Weight 290 g

Model 3951 (Modbus)

BRAND: JENCO

Description

DO & temperature Modbus RS-485 analyzer for proportional control, stored calibration data, backlit LCD for DO and temperature, universal power supply 110 to 240 VAC and packaged in an easy to install plastic panel mount water resistant 1/8 DIN IP-65 case. Uses Hamilton Company Oxysens and Easyferm DO electrodes.

  • Easy to install 1/8 DIN plastic casing

  • Clear LCDs dissolved oxygen or temperature with backlight

  • Calibration data is stored in memory and is ready for use on power-up

  • Universal power supply input from 100 ~ 240 VAC

  • Automatic or manual temperature compensation

  • RS485 Modbus communication protocol

  • CE and RoHS compliant


oxysens-120.png

Oxysense 120

PN: Wastewater W/ Membrane & 5-Meter Cable

Specifications

O Range: 0 ~ 40 ppm (mg/L)

Temperature Range: 0 to 60 °C

Pressure Tolerance: 0 to 4 bar

Response Time: 60 secs to attain 98% of actual reading

Temperature Sensor: NTC 22K °C

Thread: PG 13.5

Connector: Free

Cable Length: 5 m or other

Inline Dissolved Oxygen and Temperature Analyzer
from $195.00
Dissolved Oxygen and Temperature Controller/Transmitter
from $237.00